进口隔膜阀说明书/气动隔膜阀说明书
进口隔膜阀启闭件是一块用软质材料制成的隔膜,把阀体内腔与阀盖内腔及驱动部件隔开,故称气动隔膜阀。气动隔膜阀式指由气动执行器和隔膜阀组成,有气动执行器控制隔膜阀自动开启和关闭的隔膜阀
Ⅰ.用途和主要性能规范
Purpose and main performance specifications
1.气动衬氟管夹阀适用于一般腐蚀性流体管路上作为控制介质流体的启闭机构。
Pneumatic Pinch Valve is widely used in controling the opening and closing body fluid medium in general corrosive fluid line.
2.适用范围:
The scope of use:
衬里材质(代号)
Lining material 适用温度
Suitable temperature 适用介质
For media
Ⅱ.使用原理和结构特点
The principle and the structure characteristics
1.本阀由阀体、阀盖、阀杆、隔膜以及气缸、气缸盖、(操作)管夹等驱动零件组成。
This valve by the body and bonnet, stem and diaphragm and cylinder and the cylinder head, (operating) tube clamps etc driving parts
2.气动阀门均有手操部件,当气源发生故障而中断时,且阀门急需启、闭的紧急状态下,可顺时针旋转手轮使阀门关闭,反之则开启。
Pneumatic valves are the terminal parts, when the gas supply is interrupted failure, and valves need opened, closed under the state of emergency, clockwise handwheel valve closes, conversely open.
3.当需恢复气动操作时,必须首先旋转手轮至气缸内留有最大行程间隙后,方可输入操作气源。
When to recover pneumatic operation, must first rotation handwheel to leave in the air gap and then travel after maximum input operating air supply
Ⅲ.可能发生的故障和消除方法
Possible fault and eliminating methods
可能发生的故障
Possible fault 原因 消除方法
手轮转动不灵活
Hand wheel rotation is not flexible 阀杆上积有污垢或螺纹损伤。
阀杆螺母磨损或拉裂。
阀杆弯曲。
Dirt or the valve stem threaded plot injury
2、Stem nut wear or cracking
3. Stem bending 清除污垢或修整螺纹并涂以润滑油。
更换阀杆或螺母。
校正或更换阀杆。
1. Remove dirt or trim threads and coated with oil
2. Replace the valve stem or nuts
3. Correction or replacement of stem
供气时阀门不能自动打开
Gas supply valve cannot automatically open
1.输入气源压力过低。
2.弹簧预紧力过小。
3.胶操作薄膜磨损。
1. Input air pressure is too low
.2、Spring preload is too small
3、Wear thin 补充气源压力。
适当调节预紧压力。
更换操作隔膜。
Supplemental gas source pressure.
Proper adjustment pre-tightened stress.
3. Replace diaphragm
反馈信号失灵
Feedback signal failure
1.电源不通。
2.指示灯烧坏。
3.行程开关失灵或损坏。
4.当阀门全启或全闭时动作缓慢或不能复位。
1、Power impassability
2、Light burned out
3、Limit switch malfunction or damage
4、Slow or can not be reset when the valve is fully on or fully closed 接通电源。
更换指示灯,
调试校正或更换。
适当调整挡位圈位置。
Switch on the power.
Replace indicator light,
Debug correction or replacement.
Adjusted gears circle position.
Ⅳ. 维护保养和安装使用注意事项
Maintenance and installation using precautions
本阀必须放在干燥通风的室内,温度宜在0°C~35°C之间;相对湿度为50~80%之间,以防衬里件老化而影响使用寿命。
The valve must be placed in dry and ventilated room, the temperature should be at 0 ° C ~ 35 ° C between; relative humidity of 50 to 80%, and prevent aging of lining pieces of life.
应避免与液体燃料、油料或其它易燃物品接触。
Should be avoided with liquid fuel, oil or other flammable materials contact.
在存放期间或使用期间,应逆时针旋转手轮,使阀门处于微启状态,避免使隔膜因长期受压而失去弹性.
During storage or use during the hand wheel should rotate counter-clockwise, so that the valve is inching state, to avoid the divide and lose their elasticity due to prolonged pressure
安装前,应仔细核对管路使用条件是否与本阀规定的适用范围相符;避免因选用不当而造成不必要的损失。
Before installation, check carefully whether the conditions of pipe to use the provisions of this scope in line valve; to avoid the improper selection of unnecessary losses
安装过程中,应将阀体内腔清洗干净,避免污垢卡阻或损伤密封部件;并检查连接部位的连接螺栓是否均匀紧固。
The installation process, you should wash the body cavity to prevent dirt jamming or damage the sealing components; and check the connection parts of the connection bolts are evenly tightened.
运行中必须经常检查与介质接触的密封部位及其它易损零件;并按实际使用情况,定期更换易损部件。
Operation, you must always check the seal area contact with the media and other vulnerable parts; according to actual usage, regular replacement of wearing parts
当需要更换管夹时,应注意切勿将隔膜拧得过紧或过松。
When the need to replace tube clip,Diaphragm should not be too tight or too loose screw
在检修中,当必须打开气缸与气缸盖时,应首先排除气缸内的气源压力,然后方可拆除连接螺栓。
In the repair, when to open the cylinder and cylinder head, they should first rule out the air pressure inside the cylinder, then remove bolts
本阀如用于间断性运行的管路上,则在停止使用时,应清洗与介质接触部位,以延长阀门使用寿命。
If the valve for the intermittent operation of the pipeline, when not in use, the contact area should be cleaned with the medium to longer valve life
在手动操作阀门时,不得借助于辅助杠杆使阀门启闭,以免扭矩过大而损伤驱动零件或密封部位。
In the manual operation of the valve may not open and close the valve by means of auxiliary lever so as to avoid excessive torque while the injury-driven part or sealing parts
14.凡经检修后的阀门,应按有关规定进行密封性能试验,合格后方能安装使用,并作好记录以供查考。
After all, after the valve repair, according to relevant provisions of the sealing performance test, qualified before installation and make records for the traced
|